Illustrative scenario

A furnace over-cycling, seen on the air and gas traces together

Illustrative scenario — representative of common industrial IoT applications

Compressed airNatural gasMetal Fabrication & FinishingBuilding Materials & Heavy Industry

Short-cycling that neither the gas bill nor the air system showed alone.

A heat-treating operation

No client is named, no logo is shown and no figure here was measured at any site (R2).

How it went.

Every study on this site runs the same four beats, in the same order.

  1. 01

    Alert

    A furnace was firing far more often than the process required. On a monthly gas bill it looked like ordinary seasonal variation.

  2. 02

    Cost

    2 utilities on one chart — The over-cycling pattern is only obvious when gas firing and air demand are overlaid.

  3. 03

    Fix

    Gas flow metering at the furnace · Compressed-air demand at the same asset · Firing-rate trending on one shared time axis

  4. 04

    Restored

    One overlaid trace where the cycling is unmistakable

In full.

Illustrative scenario — representative of common industrial IoT applications.

The problem

A furnace was firing far more often than the process required. On a monthly gas bill it looked like ordinary seasonal variation.

What would be installed

  • Gas flow metering at the furnace
  • Compressed-air demand at the same asset
  • Firing-rate trending on one shared time axis

What changes

Before — Two utilities, two bills, no pattern After — One overlaid trace where the cycling is unmistakable

The number

2 utilities on one chart — The over-cycling pattern is only obvious when gas firing and air demand are overlaid. Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]

In one line

Two traces on one axis is often the entire analysis.

What the data looked like.

Hover or arrow-key across the trace to read any interval. The flagged point is the one that started the conversation.

A furnace over-cycling, seen on the air and gas traces together
STEADY-STATE DEMAND
GAS FIRING RATE · 6 H · 2-MIN · DASHED = STEADY-STATE DEMAND
Chart data
IntervalFurnace 2 (m³/h)
06:0097
06:0297
06:0497
06:063.2
06:084.8
06:105.0
06:123.1
06:1495
06:1696
06:1896
06:204.6
06:224.1
06:243.5
06:264.0
06:2895
06:3096
06:3297
06:342.8
06:363.4
06:382.7
06:403.7
06:4295
06:4496
06:4697
06:485.5
06:502.8
06:523.1
06:544.5
06:5696
06:5897
07:0096
07:023.6
07:043.7
07:065.0
07:083.1
07:1095
07:1297
07:1497
07:165.3
07:184.6
07:203.7
07:224.7
07:2497
07:2696
07:2897
07:302.5
07:325.2
07:344.8
07:362.7
07:3897
07:4095
07:4297
07:443.2
07:462.6
07:484.2
07:504.0
07:5297
07:5497
07:5695
07:583.7
08:003.9
08:024.4
08:044.8
08:0697
08:0897
08:1097
08:122.7
08:143.7
08:165.5
08:183.9
08:2096
08:2298
08:2497
08:265.3
08:284.4
08:303.0
08:324.8
08:3496
08:3696
08:3897
08:403.2
08:422.6
08:443.8
08:464.7
08:4897
08:5096
08:5297
08:545.3
08:563.1
08:582.8
09:004.8
09:0295
09:0496
09:0696
09:083.3
09:104.4
09:124.1
09:143.4
09:1698
09:1897
09:2096
09:224.5
09:244.8
09:263.7
09:284.3
09:3095
09:3296
09:3497
09:363.8
09:385.4
09:403.0
09:424.8
09:4495
09:4697
09:4897
09:502.8
09:525.2
09:544.7
09:565.0
09:5895
10:0097
10:0296
10:045.4
10:064.9
10:084.6
10:103.8
10:1295
10:1497
10:1695
10:183.8
10:205.1
10:224.5
10:244.4
10:2695
10:2897
10:3096
10:324.2
10:345.3
10:364.0
10:383.6
10:4097
10:4296
10:4497
10:464.5
10:483.2
10:502.6
10:522.9
10:5496
10:5695
10:5895
11:003.5
11:024.7
11:045.1
11:063.8
11:0896
11:1096
11:1298
11:144.5
11:163.6
11:185.5
11:203.5
11:2296
11:2497
11:2696
11:284.3
11:302.9
11:323.2
11:344.4
11:3695
11:3896
11:4097
11:423.0
11:442.5
11:464.5
11:483.9
11:5095
11:5295
11:5497
11:565.4
11:583.4
Before and after, in words
BeforeTwo utilities, two bills, no pattern
AfterOne overlaid trace where the cycling is unmistakable

Illustrative dataset — a representative operational profile, seeded and deterministic, not measured at any site.

What changed.

Before

Two utilities, two bills, no pattern

After

One overlaid trace where the cycling is unmistakable

2 utilities

on one chart

The over-cycling pattern is only obvious when gas firing and air demand are overlaid.

Source: Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]

Find out what’s hiding in your plant.

Half a day on your floor, no charge and no obligation. At the end of it we tell you what we saw, what we would meter first, and what the return looks like.

Your first opportunity assessment is free.

Book a free consultationAll case studies

or call 1-833-QUANTFY (1-833-782-6839)