Illustrative scenario

Chiller circuit leak isolated without a shutdown

Illustrative scenario — representative of common industrial IoT applications

WaterManufacturing — automotive, plastics & rubber

A leaking cooling loop found and isolated with the line still running.

An automotive plant

No client is named, no logo is shown and no figure here was measured at any site (R2).

How it went.

Every study on this site runs the same four beats, in the same order.

  1. 01

    Alert

    A closed cooling loop was making up far more water than a closed loop should. Nobody knew which of several circuits was responsible.

  2. 02

    Cost

    1 loop isolated — Identified by sub-meter divergence, with no production stoppage.

  3. 03

    Fix

    Sub-meters on each cooling circuit's make-up line · Continuous differential comparison between circuits · Threshold alerting on make-up rate

  4. 04

    Restored

    One circuit named, isolated and repaired on a planned outage

In full.

Illustrative scenario — representative of common industrial IoT applications.

The problem

A closed cooling loop was making up far more water than a closed loop should. Nobody knew which of several circuits was responsible.

What would be installed

  • Sub-meters on each cooling circuit’s make-up line
  • Continuous differential comparison between circuits
  • Threshold alerting on make-up rate

What changes

Before — One aggregate make-up figure, four candidate circuits After — One circuit named, isolated and repaired on a planned outage

The number

1 loop isolated — Identified by sub-meter divergence, with no production stoppage. Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]

In one line

Sub-metering does not find leaks. It narrows them until the answer is obvious.

What the data looked like.

Hover or arrow-key across the trace to read any interval. The flagged point is the one that started the conversation.

Chiller circuit leak isolated without a shutdown
MAKE-UP WATER BY CIRCUIT · 7 DAYS · 4-HOURLY
Chart data
IntervalLoop A (L/h)Loop B (L/h)Loop C (L/h)
D1 0:00212123
D1 4:00211926
D1 8:00241927
D1 12:00201932
D1 16:00242136
D1 20:00221736
D2 0:00222139
D2 4:00211840
D2 8:00252145
D2 12:00202045
D2 16:00202053
D2 20:00252052
D3 0:00221855
D3 4:00222157
D3 8:00241860
D3 12:00201761
D3 16:00201867
D3 20:00242069
D4 0:00241772
D4 4:00232074
D4 8:00231778
D4 12:00212078
D4 16:00241982
D4 20:00232081
D5 0:00201788
D5 4:00221887
D5 8:00201990
D5 12:00211994
D5 16:00201995
D5 20:002318100
D6 0:002420102
D6 4:002020103
D6 8:002019105
D6 12:002217111
D6 16:002019113
D6 20:002220115
D7 0:002019119
D7 4:002320122
D7 8:002320122
D7 12:002219125
D7 16:002120129
D7 20:002117129
Before and after, in words
BeforeOne aggregate make-up figure, four candidate circuits
AfterOne circuit named, isolated and repaired on a planned outage

Illustrative dataset — a representative operational profile, seeded and deterministic, not measured at any site.

What changed.

Before

One aggregate make-up figure, four candidate circuits

After

One circuit named, isolated and repaired on a planned outage

1 loop

isolated

Identified by sub-meter divergence, with no production stoppage.

Source: Illustrative scenario, not a client result. Figure is representative, not measured. [TOM-REVIEW]